Model: NEP BDM 600X
Input data (DC)
Recommended max. photovoltaic power (Wp) 2 x max. 450
Max. open circuit DC voltage (Vdc) 60
Max. input direct current (Adc) 14 x 2
MPPT tracking accuracy > 99.5%
MPPT tracking range (Vdc) 22-55
Isc PV (absolute maximum) (Adc) 18 x 2
Maximum power feed from
Inverter to solar cell array (Adc) 0
Output current (AC)
Max.AC output peak power (Wp) 600
THD < 3 % (at rated power)
Phase angle (cos phi, fixed) > 0.99 (at rated power)
(Inrush) current (peak and continuous) 24 A, 15 us
Maximum output fault current (Aac) 4.4 A peak
Maximum output overcurrent protection (Aac) 10
Efficiency
Weighted average efficiency (CEC) 95.50%
Compensation loss at night (Wp) 0.11
Protective function
Over/under voltage protection Yes
Over/under frequency protection Yes
Anti-islanding protection Yes
Overcurrent protection Yes
Protection against reverse DC polarity Yes
Overload protection Yes
Protection class NEMA-6 / IP-66 / IP-67
Ambient temperature -40 °F to +149 °F (-40 °C to +65 °C)
Operating temperature -40 °F to +185 °F (-40 °C to +85 °C)
Display LED LAMP
Communication Powerline
Dimensions (W x H x D) 10.91 inches x 5.20 inches x 1.97 inches (277 mm x 132 mm x 50 mm)
Weight 6.4 lbs. (2.9 kg)
Environmental category indoor and outdoor areas
Suitable for damp locations
Degree of contamination: Degree of contamination 3
Overvoltage category II (solar power), III (mains power)
Product safety compliance UL 1741, CSA C22.2, No. 107.1, IEC/EN 62109-, IEC/EN 62109-2
Compliance with network and system rules* (see type plate
for details on compliance with these rules): IEEE 1547, VDE-AR-N 4105*, VDE V 0126-1-1/A1, G83/2, CEI 021, AS 4777.2 & AS 4777.3, EN50438